Product

ACP Double Syringe

ACP double-syringe system is used to facilitate the safe and rapid preparation of autologous platelet-rich plasma (PRP)

SynergyUHD4™ 4K

SynergyUHD4™ 4K imaging is a commanding imaging platform offered by Arthrex® featuring a true UHD 4K

Scorpion™

The Scorpion™ suture passers are used in Shoulder Arthroscopy for Rotator Cuff and Labral Repair.

InternalBrace™ 

Ligament Augmentation Repair Resize the browser window to see the responsive effect 

News release


 

 

InternalBrace™ Ligament Augmentation Repair The Body's Internal Seat Belt

The InternalBrace™ ligament augmentation system is used to repair lateral or medial ankle instability. Similar to wearing a seat belt for support, this innovative technique helps to support the ankle and prevent the possibility of secondary injury.

 

ACP Autologous Conditioned Plasma

The Arthrex ACP® double-syringe system provides rapid and efficient concentration of platelets and growth factors from platelet-rich plasma (PRP) for use at the patient’s point of care. The Arthrex ACP double-syringe system preparation requires less blood to be drawn than other PRP systems reducing the time and resources needed to administer the PRP treatment. Its unique double-syringe design allows for convenience and safe handling of the biological treatment

 

Arthrex Synergy Suite Experience

The Synergy Operating Room Integration Suite is equipped with the latest in 4K imaging, integration and resection technology. This state‐of‐the‐art technology can increase efficiency, lower cost of ownership and positively impact the patient experience.

 

Knee Scorpion™ Suture Passer - Meniscal Vertical Repair    

The Knee Scorpion™ suture passer automatically passes and retrieves either the 2-0 or zero FiberWire® suture. The low profile design of the Knee Scorpion allows access to tight recesses of the knee for various stitch configurations. Multiple circumferential sutures are shown in this animation to repair a vertical meniscus tear.

Responsive Column Cards

Resize the browser window to see the effect.

Avatar
Hello World
Avatar
Hello World
Avatar
Hello World
Avatar
Hello World
Avatar
Hello World
Avatar
Hello World

 News release

 


What's New at Device Innovation

ACP Double Syringe

ACP double-syringe system is used to facilitate the safe and rapid preparation of autologous platelet-rich plasma (PRP)

SynergyUHD4™ 4K

SynergyUHD4™ 4K imaging is a commanding imaging platform offered by Arthrex® featuring a true UHD 4K

Scorpion™

The Scorpion™ suture passers are used in Shoulder Arthroscopy for Rotator Cuff and Labral Repair.

InternalBrace™

Ligament Augmentation Repair Resize the browser window to see the responsive effect                    . 

SutureTak

AR-1934BCF-2

3.0 mm BioComposite SutureTak with two #2 FiberWire

AR-1934BCF-24-2

2.4 mm BioComposite SutureTak with two #2 FiberWire

AR-1938BC

Knotless SutureTak Suture Anchor, 3 mm x 12.7 mm, #2 FiberWire CL

AR-1320BNF

Micro Bio-SutureTak 2.4 x 6.5 mm with Needles with 2-0 FiberWire

AR-1934BCF-24-2

Small Joint Bio-SutureTak w/Needles 3x14.5 mm w/#1 FiberWire

AR-1934BCF-24

2.4 mm BioComposite SutureTak Needles 3x14.5 mm w/#1 FiberWire

AR-1934PS

PEEK SutureTak 3.0 mm. w/#2 FiberWire ..........................................................

AR-1934BCF

3.0 mm BioComposite SutureTak  .............................................................

SutureLasso

AR-4065B

SutureLasso,Banana ..................

AR-4065W

SutureLasso, 45 ํ w/Wire Loop

AR-4065-90W

SutureLasso,90 ํ w/Wire Loopk

AR-4065-45L

Corkscrew SutureLasso,45 ํ curve left

AR-4065-45R

Corkscrew SutureLasso, 45 ํcurve right

AR-4068-25TL

SutureLasso, SD 25 ํ Tight Curve Left

AR-4068-25TR

SutureLasso, SD 25 ํ Tight Curve Right

AR-4068-45L

SutureLasso,SD 45 ํcurve left w

AR-4068-45R

SutureLasso,SD 45 ํ curve right w

AR-4068C

SutureLasso,SD 45 ํ Crescent w

AR-4068-90

SutureLasso,SD 90 ํ Strightt w

AR-4068-90L

SutureLasso,SD 90 ํ curveleft w

AR-4068-90R

SutureLasso,SD 90 ํcurve right w

AR-8701

Micro SutureLasso, Minor bend

AR-8702

Micro SutureLasso, Major bend

AR-8703

Micro SutureLasso, straight..................................................

AR-8701SR

Micro SutureLasso,Suture Retriever

AR-8704

Micro SutureLasso, TFCC, Short 70 bend

AR-4068-05SD

SutureLasso,SD Wire Loop .......

New Product

Shoulder

Mountains

Hand & Wris

Knee

Shoulder

Mountains

FiberWire

Other

New Product

 

FAQ

Featuring : Thomas O . Clanton , M.D., and William McGarvey , M.D., Houston TX on Tenodesis Technique for Foot & Ankle Reconstruction

Avatar

In foot and ankle reconstructions what distinct advantages have you found in performing the technical procedure as well as patient recovery using the principles of interference screw fit fixation with the tenodesis technique versus predicate bone tunnel and tendon to tendon suture repair ?

11:00
Avatar

The tenodesis technique allows for smaller incisions for exposure , less dissection,less bone destruction with drill holes. If immediate tendon fixation is unsatisfactory , it can be taken out and replaced after changing tension of tendon fixation. The Bio-Tenodesis Screws aviod metal that can make revision surgery difficult and can produce artifact on MRI.

11:01
Avatar

For which procedures in foot and ankle reconstructions have you found the tenodesis technique to be effective and what biomechanical testing have you performed to support these indications?

11:02
Avatar

The Bio-Tenodesis Technique is effective for lateral ankle ligament reconstructions with free tendon graft (semitendinosus or gracilis) for revision reconstructions , and also for FHL to calcaneus for chronic Achilles rupture , FDL or FHL to navicular for posterior tibial tendon reconstruction and posterior tibial tendon through interosseous membrane to lateral cuneiform for drop foot . We have done mechanical testing in the lab and shown pull-out strengths greater than the 50N strength that is necessary for such procedures.

11:05
Avatar

Given the various planes and degree of motion in the foot and ankle explain the advantages of anatomically tensioning the tendon prior to proceeding with final tenodesis screw fixation for the more common procedures?

11:08
Avatar

It is necessary to tension the graft anatomically to confirm that the graft will not “Capture the joint ” and prevent normal range of motion. This is particularly important for lateral ankle ligament reconstruction where limiting subtalar motion excessively can lead to postoperative pain. The tenodesis technique allows the surgeon the opportunity to test tension of the fixation prior to final fixation. See the In the Loop section for more information.

11:10
Avatar

What technical pearls would you offer your colleagues regarding the use of the tenodesis technique for foot and ankle reconstruction and does the stronger fixation principle lend to a more fuctional rehabilition program?

11:12
Avatar

It is important to become familiar with the instrumentation and method for utilizing it prior to getting into O.R. Proper sizing of the graft and screw is important for rigid fixation. Such fixational recovery.

11:15
Avatar

What role do suture anchors play in foot and ankle surgery versus the tenodesis technique?

11:17
Avatar

Certain situations such as acute ligament avulsion directly from bone lend themselves to easier fixation with suture anchors.

11:20
Visitors: 97,346